home *** CD-ROM | disk | FTP | other *** search
/ HAM Toolkit / HAM Toolkit.iso / text / arrl / faqelec1.txt < prev    next >
Internet Message Format  |  1994-01-25  |  51KB

  1. From arrl.org!psinntp!psinntp!news.intercon.com!howland.reston.ans.net!torn!nott!cunews!revcan!ecicrl!clewis Mon Jan 17 14:54:59 1994
  2. Xref: arrl.org sci.electronics:1013 news.answers:384
  3. Path: arrl.org!psinntp!psinntp!news.intercon.com!howland.reston.ans.net!torn!nott!cunews!revcan!ecicrl!clewis
  4. From: clewis@ferret.ocunix.on.ca (Chris Lewis)
  5. Newsgroups: misc.consumers.house,rec.woodworking,sci.electronics,news.answers,misc.answers,rec.answers,sci.answers
  6. Subject: Electrical Wiring FAQ [Part 1/2]
  7. Summary: A series of questions and answers about house wiring
  8. Message-ID: <wirefaq.1_758443198@ferret.ocunix.on.ca>
  9. Date: 13 Jan 94 06:40:26 GMT
  10. Expires: 10 Feb 94 06:39:58 GMT
  11. Reply-To: wirefaq@ferret.ocunix.on.ca (Wiring FAQ commentary reception)
  12. Followup-To: poster
  13. Lines: 1040
  14. Approved: news-answers-request@mit.edu
  15. Supersedes: <wirefaq.1_757233572@ferret.ocunix.on.ca>
  16.  
  17. Archive-name: electrical-wiring/part1
  18. Last-modified: Thu Dec  2 02:20:51 EST 1993
  19.  
  20.         Frequently Asked Questions on Electrical Wiring
  21.  
  22.                         Copyright 1991, 1992, 1993
  23.         Steven Bellovin (smb@research.att.com)
  24.         Chris Lewis (clewis@ferret.ocunix.on.ca)
  25.  
  26.         Redistribution for profit, or in altered content/format
  27.         prohibited without permission of the authors.
  28.  
  29.         Comments to (automatic if you reply to this article):
  30.             wirefaq@ferret.ocunix.on.ca
  31.  
  32. This FAQ is formatted as a digest.  Most news readers can
  33. skip from one question to the next by pressing ^G.
  34.  
  35. Answers to many other topics related to houses can be obtained from
  36. the misc.consumers.house archive; send an empty piece of mail to
  37. house-archive@dg-rtp.dg.com for information.
  38.  
  39. Changes to previous issue marked with "|" in left column.  Watch
  40. particularly for "NEW" in the Questions list for new or substantively
  41. changed answers.  "g^|" will get you to the changed sections quickly
  42. in most newsreaders.
  43.  
  44. Subject: Questions answered in this FAQ
  45.  
  46.     Introduction/Disclaimers
  47.     What is the NEC?  Where can I get a copy?
  48.     What is the CEC?  Where can I get a copy?
  49.     Can I do my own wiring?  Extra pointers?
  50.     What do I need in the way of tools?
  51.     What is UL listing?
  52.     What is CSA approval?
  53.     Are there any cheaper, easier to read books on wiring?
  54.     Inspections how and what?  Why should I get my wiring inspected?
  55.     My house doesn't meet some of these rules and regulations.
  56.     A word on voltages: 110/115/117/120/125/220/240
  57.     What does an electrical service look like?
  58.     What is a circuit?
  59.     "grounding" versus "grounded" versus "neutral".
  60.     What does a fuse or breaker do?  What are the differences?
  61.     Breakers?  Can't I use fuses?
  62.     What size wire should I use?
  63.     Where do these numbers come from?
  64.     What does "14-2" mean?
  65.     What is a "wirenut"/"marrette"/"marr connector".  How are they used?
  66.     What is a GFI/GFCI?
  67.     Where should GFCIs be used?
  68.     Where shouldn't I use a GFCI?
  69.     What is the difference between a GFCI outlet and a GFCI breaker?
  70.     What's the purpose of the ground prong on an outlet, then?
  71.     Why is one prong wider than the other?  Polarization
  72.     How do I convert two prong receptacles to three prong?
  73.     Surges, spikes, zaps, grounding and your electronics
  74.     Are you sure about GFCIs and ungrounded outlets?
  75.         Should the test button work?
  76.     What kind of outlets do I need in a kitchen?
  77.     Where must outlets and switches be in bathrooms?
  78.     General outlet placement rules/line capacities
  79.     What is Romex/NM/NMD?  What is BX?  When should I use each?
  80.     Should I use plastic or metal boxes?
  81.     Junction box positioning?
  82.     Can I install a replacement fixture?
  83.     Noisy fluorescent fixtures, what do I do?
  84.     What does it mean when the lights brighten when a motor starts?
  85.     What is 3 phase power?  Should I use it?  Can I get it in my house?
  86.     Is it better to run motors at 110 or 220?
  87.     What is this nonsense about 3HP on 110V 15A circuits?
  88.     How should I wire my shop?
  89.     Underground wiring
  90.     Doorbell/telephone/cable other service wiring hints
  91.     Aluminum wiring
  92.     I'm buying a house!  What should I do?
  93. |    What is this weird stuff?  Old style wiring
  94.     Where do I buy stuff?
  95.     Copper wire characteristics table
  96.  
  97.  
  98. Subject: Introduction/Disclaimers
  99.  
  100.     Although we've done a fair bit of wiring, we are not
  101.     electricians, and we cannot be responsible for what you do.  If
  102.     you're at all uncertain about what is correct or safe, *don't
  103.     do it*.  Contact someone qualified -- a licensed electrician,
  104.     or your local electrical inspector.  Electricity is no joke;
  105.     mistakes can result in shocks, fires, or electrocution.
  106.  
  107.     Furthermore, our discussion is based on the U.S. National
  108.     Electrical Code (NEC) and the Canadian Electrical code (CEC).
  109.     To the best of our abilities, we have confirmed every detail
  110.     with the electrical code, but we don't quote sections
  111.     simply to keep this thing readable.  If you think we're wrong,
  112.     we invite you to correct us, but please - quote references!
  113.  
  114.     The NEC and the CEC do not, in and of themselves, have the
  115.     force of law.  Many municipalities adopt it en toto.  Others,
  116.     however, do not.  Check your with your local building
  117.     department (and <provincial> Hydro Inspection Offices in
  118.     Canada) to find out what applies in your area.  Also,
  119.     your local electrical utility may also have special requirements
  120.     for electrical service installation.  Bear in mind, too, that
  121.     we say here applies primarily to ordinary single-family
  122.     residences.  Multi-family dwellings, mobile homes, commercial
  123.     establishments, etc., are sometimes governed by different
  124.     rules.
  125.  
  126.     Also note that, contrary to popular belief in the U.S. (and in
  127.     some parts of Canada), Canada is not a wholly-owned subsidiary
  128.     of the U.S.  Consequently, the NEC does not apply in Canada.
  129.     Lots of things are the same, including voltages, line
  130.     frequencies, and the laws of physics.  But there are a number
  131.     of crucial differences in the regulations.  Where we can, we've
  132.     noted them, flagging the relevant passages with ``NEC'' or
  133.     ``CEC''.
  134.  
  135.     Remember that the CEC and NEC are minimal standards.  It is often
  136.     smart to go beyond their minimal requirements.
  137.  
  138. Subject: What is the NEC?  Where can I get a copy?
  139.  
  140.     The NEC is a model electrical code devised and published by the
  141.     National Fire Protection Association, an insurance industry group.
  142.     It's revised every three years.  The 1993 version has been released.
  143.     You can buy a copy at a decent bookstore, or by calling them directly
  144.     at 800-344-3555.  The code exists in several versions.  There's the
  145.     full text, which is fairly incomprehensible.  There's an abridged
  146.     edition, which has only the sections likely to apply to most houses.
  147.     And there's the NEC Handbook, which contains the ``authorized
  148.     commentary'' on the code, as well as the full text.  That's the
  149.     recommended version.  Unfortunately, there's no handbook for
  150.     the abridged edition.  And the full handbook is expensive --
  151.     US$65 plus shipping and handling.
  152.  
  153. Subject: What is the CEC?  Where can I get a copy?
  154.  
  155.     The Canadian Standards Association is an organization made up
  156.     of various government agencies, power utilities, insurance
  157.     companies, electrical manufacturers and other organizations.
  158.     The CSA publishes CSA Standard C22.1 which is updated every two
  159.     or three years.  Each province adopts, with some amendments,
  160.     this standard and publishes a province-specific code book.
  161.     Since each province publishes its own slightly modified
  162.     standard, it would be somewhat confusing to obtain the CSA
  163.     standard itself.  In this FAQ, "CEC" really means the
  164.     appropriate provincial standard.  In particular, this FAQ is
  165.     derived from the Ontario Hydro Electrical Safety Code, 20th
  166.     edition (1990).  Which is in turn based on CSA C22.1-1990 (16th
  167.     edition).  While differences exist between the provinces, an
  168.     attempt has been made to avoid specific-to-Ontario detail.
  169.  
  170.     The appropriate provincial code can be obtained from electrical
  171.     inspection offices of your provincial power authority.  In
  172.     Ontario, it's Ontario Hydro.  The Ontario Hydro book isn't
  173.     overly fat.  It's about C$25, and includes mailed updates.  I
  174.     hear that these standards are somewhat easier to read than the
  175.     equivalent NEC publications.
  176.  
  177.     Don't bother asking in Quebec - DIY wiring is banned throughout
  178.     the province.
  179.  
  180. Subject: Can I do my own wiring?  Extra pointers?
  181.  
  182.     In most places, homeowners are allowed to do their own wiring.
  183.     In some, they're not.  Check with your local electrical
  184.     inspector.  Most places won't permit you to do wiring on other's
  185.     homes for money without a license.  Nor are you permitted to do
  186.     wiring in "commercial" buildings.  Multiple dwellings (eg: duplexes)
  187.     are usually considered "semi-commercial" or "commercial".  However,
  188.     many jurisdictions will permit you to work on semi-commercial
  189.     wiring if you're supervised by a licensed electrician - if you can
  190.     find one willing to supervise.
  191.  
  192.     If you do your own wiring, an important point:
  193.  
  194.     Do it NEAT and WELL!  What you really want to aim for is a better
  195.     job than an electrician will do.  After all, it's your own home,
  196.     and it's you or your family that might get killed if you make
  197.     a mistake.  An electrician has time pressures, has the skills
  198.     and knows the tricks of the trade to do a fast, safe job.
  199.     In this FAQ we've consciously given a few recommendations that
  200.     are in excess of code, because we feel that it's reasonable,
  201.     and will impress the inspector.
  202.  
  203.     The inspector will know that you're an amateur.  You have to
  204.     earn his trust.  The best way of doing this is to spend your
  205.     time doing as neat a job as possible.  Don't cut corners.
  206.     Exceed specifications.  Otherwise, the inspector may get extremely
  207.     picky and fault you on the slightest transgressions.
  208.  
  209.     Don't try to hide anything from the inspector.
  210.  
  211.     Use the proper tools.  Ie: don't use a bread knife to strip
  212.     wires, or twist wires with your fingers.  The inspector
  213.     won't like it, and the results won't be that safe.  And it
  214.     takes longer.  And you're more likely to stick a hunk of
  215.     12ga wire through your hand that way.
  216.  
  217.     Don't handle house wire when it's very cold (eg: below -10C
  218.     or 16F).  Thermoplastic house wire, particularly older types
  219.     become very brittle.
  220.  
  221. Subject: What do I need in the way of tools?
  222.  
  223.     First, there's the obvious -- a hammer, a drill, a few
  224.     screwdrivers, both straight and Phillips-head.  If you're 
  225.     lucky enough to live in Canada (or find a source of CSA-approved
  226.     devices) you need Robertson ("square recess") screwdrivers
  227.     (#1 and #2) instead of phillips.
  228.  
  229.     For drilling a few holes, a 3/4" or 1" spade bit and 1/4" or
  230.     3/8" electric drill will do.  If you're doing a lot, or
  231.     are working with elderly lumber, we recommend a 1/2" drill
  232.     (right-angle drills are wonderful.  Can be rented) and
  233.     3/4" or 1" screw-point auger drill bits.  These bits pull
  234.     you through, so they're much faster and less fatiguing, even
  235.     in 90 year old hardwood timbers.
  236.  
  237.     Screw-driver bits are useful for drills, expecially if you
  238.     install your electrical boxes using screws (drywall screws
  239.     work well).
  240.     
  241.     For stripping wire, use a real wire stripper, not a knife or
  242.     ordinary wire cutters.  Don't buy the $3 K-mart "combo stripper,
  243.     crimper and bottle opener" types.  You should expect to pay
  244.     $15 to $20 for a good "plier-type" pair.  It will have sized
  245.     stripping holes, and won't nick or grab the wire - it should
  246.     be easy to strip wire with it.  One model has a small hole in the
  247.     blade for forming exact wire loops for screw terminals.  There
  248.     are fancier types (autostrip/cut), but they generally aren't
  249.     necessary, and pros usually don't use them.
  250.  
  251.     A pair of diagonal side cutter pliers are useful for clipping ends
  252.     in constricted places.  Don't use these for stripping wire.
  253.  
  254.     You will need linesman pliers for twisting wires for wire nuts.
  255.  
  256.     You should have a pair of needle-nose pliers for fiddling
  257.     inside boxes and closing loops, but it's better to form wire
  258.     loops with a "loop former hole" on your wire stripper - more
  259.     accurate.
  260.  
  261.     If you're using non-metallic cable, get a cable stripper for
  262.     removing the sheath.  Or, do what some pros do, they nick the
  263.     end of the sheath, grab the ground wire with a pair of pliers,
  264.     and simply rip the sheath back using the ground wire as a
  265.     "zipper", and cut the sheath off.  You shouldn't try to strip
  266.     the sheath with a knife point, because it's too easy to
  267.     slash the insulation on the conductors.  Apparently Stanley
  268.     utility knives fitted with linoleum cutters (hooked blades)
  269.     can be used to strip sheath, but there is still the possibility
  270.     that you'll gouge the conductors.
  271.  
  272.     For any substantial amount of work with armored cable, it's well
  273.     worth your while to invest in a rotary cable splitter (~US$ 18).
  274.     Hack saws are tricky to use without cutting into the wire
  275.     or the insulation.
  276.  
  277.     Three-prong outlet testers are a quick check for properly-wired
  278.     outlets.  About $6.  Multimeters tell you more, but are a lot more
  279.     expensive, and probably not worth it for most people.  A simple
  280.     voltage sensor, which can detect potential through an insulated
  281.     wire not supplying any devices, is extremely helpful; they cost
  282.     about US$ 10 at Radio Shack.
  283.  
  284.     You should have a voltage detector - to check that the wires are
  285.     dead before doing work on them.  Neon-bulb version are cheap ($2-3)
  286.     and work well.  If you get more serious, a "audible alarm" type is
  287.     good for tracing circuits without a helper.  (Though I've been known
  288.     to lock the drill on, and hit breakers until the scream stops ;-)
  289.  
  290.     For running wires through existing walls, you need fish tape.
  291.     Often, two tapes are needed, though sometimes, a bent hanger or
  292.     a length of thin chain will suffice.  Fish tapes can be rented.
  293.  
  294.     Electrical tape.  Lots of it ;-)  Seriously, a good and competent
  295.     wiring job will need very little tape.  The tape is useful for
  296.     wrapping dicy insulation in repair work.  Another use is to wrap 
  297.     around the body of outlets and switches to cover the termination
  298.     screws - I don't do this, but drywall contractors prefer it (to
  299.     prevent explosions when the drywall knife collides with a live outlet
  300.     that has no cover plate).
  301.  
  302. Subject: What is UL listing?
  303.  
  304.     The UL stands for "Underwriters Laboratory".  It used to be
  305.     an Insurance Industry organization, but now it is independent
  306.     and non-profit.  It tests electrical components and equipment
  307.     for potential hazards.  When something is UL-listed, that means
  308.     that the UL has tested the device, and it meets their requirements
  309.     for safety - ie: fire or shock hazard.  It doesn't necessarily
  310.     mean that the device actually does what it's supposed to, just
  311.     that it probably won't kill you.
  312.  
  313.     The UL does not have power of law in the U.S. -- you are
  314.     permitted to buy and install non-UL-listed devices.  However,
  315.     insurance policies sometimes have clauses in them that will
  316.     limit their liability in case of a claim made in response to
  317.     the failure of a non-UL-listed device.  Furthermore, in
  318.     many situations the NEC will require that a wiring component
  319.     used for a specific purpose is UL-listed for that purpose.
  320.     Indirectly, this means that certain parts of your wiring
  321.     must be UL-listed before an inspector will approve it and/or
  322.     occupancy permits issued.
  323.     
  324. Subject: What is CSA approval?
  325.  
  326.     Every electrical device or component must be certified by the
  327.     Canadian Standards Association before it can be sold in
  328.     Canada.  Implicit in this is that all wiring must be done
  329.     with CSA-approved materials.  They perform testing similar to
  330.     the UL (a bit more stringent), except that CSA approval is
  331.     required by law.
  332.  
  333.     Again, like the UL, if a fire was caused by non-CSA-approved
  334.     equipment, your insurance company may not have to pay the
  335.     claim.
  336.  
  337.     Note: strictly speaking, there usually is a legal way around the
  338.     lack of a CSA sticker.  In some cases (eg: Ontario), a local hydro
  339.     inspection prior to purchase, or prior to use, is acceptable.
  340.     The hydro inspector will affix a "hydro sticker" to the unit, which
  341.     is as good as CSA approval.  But it costs money - last I knew,
  342.     $75 per unit inspected.
  343.  
  344.     ULC (Underwriters Laboratory of Canada) is an independent organization
  345.     that, amongst other things, undertakes the quarterly inspection of
  346.     manufacturer's to ensure continued compliance of UL Listed/Recognized
  347.     products to Agency reports and safety standards. This work is done under
  348.     contract to UL Inc (Follow-up Services Division). They are not
  349.     a branch or subsidiary of UL.
  350.  
  351.  
  352.  
  353.  
  354. Subject: Are there any cheaper, easier to read books on wiring?
  355.  
  356.     USA: The following three books were suggested by our readers
  357.  
  358.         Residential Wiring
  359.         by Jeff Markell,
  360.         Craftsman Books,
  361.         Carlsbad CA for $18.25. ISBN 0-934041-19-9.
  362.  
  363.         Practical Electrical Wiring
  364.         Residential, Farm and Industrial,  Based on the National
  365.         Electrical Code    ANSI/NFPA 70
  366.         Herbert P. Richter and W. Creighton Schwan
  367.         McGraw-Hill Book Co.
  368.  
  369.         Wiring Simplified
  370.         H. P. Richter and W. C. Schwan
  371.         Park Publishing Co.
  372.     
  373.     Try to make sure that the book is based on the latest NEC
  374.     revision.  Which is currently 1993.
  375.  
  376.     Canada: P.S. Knight authors and publishes a book called
  377.     "Electrical Code Simplified".  There appears to be a version
  378.     published specific to each province, and is very tied into the
  379.     appropriate provincial code.  It focuses on residential wiring,
  380.     and is indispensible for Canadian DIY'ers.  It is better to get
  381.     this book than the CEC unless you do a lot of wiring (or answer
  382.     questions on the net ;-).
  383.  
  384.     It is updated each time the provincial codes are.  This book is
  385.     available at all DIY and hardware stores for less than C$10.
  386.  
  387. Subject: Inspections how and what?  Why should I get my wiring inspected?
  388.  
  389.     Most jurisdictions require that you obtain a permit and
  390.     inspections of any wiring that is done.  Amongst other more
  391.     mundane bureaucratic reasons (like insurance companies not
  392.     liking to have to pay claims), a permit and inspections
  393.     provides some assurance that you, your family, your neighbors
  394.     or subsequent owners of your home don't get killed or lose
  395.     their homes one night due to a sloppy wiring job.
  396.  
  397.     Most jurisdictions have the power to order you to vacate your
  398.     home, or order you to tear out any wiring done without a
  399.     permit.  California, for instance, is particularly nasty about
  400.     this.
  401.  
  402.     If fire starts in your home, and un-inspected wiring is at
  403.     fault, insurance companies will often refuse to pay the damage
  404.     claims.
  405.  
  406.     In general, the process goes like this:
  407.         - you apply to your local inspections office or building
  408.           department for a permit.  You should have a sketch or
  409.           detailed drawing of what you plan on doing.  This is
  410.           a good time to ask questions on any things you're not
  411.           sure of.  If you're doing major work, they may impose
  412.           special conditions on you, require loading
  413.           calculations and ask other questions.  At this point
  414.           they will tell you which inspections you will need.
  415.         - If you're installing a main panel, you will need to
  416.           have the panel and service connections inspected
  417.           before your power utility will provide a connection.
  418.           This is sometimes done by the local power authority
  419.           rather than the usual inspectors.
  420.         - After installing the boxes and wiring, but before
  421.           the insulation/walls go up, you will need a
  422.           "rough-in" inspection.
  423.         - After the walls are up, and the wiring is complete,
  424.           you will need a "final inspection".
  425.  
  426. Subject: My house doesn't meet some of these rules and regulations.
  427.     Do I have to upgrade?
  428.  
  429.     In general, there is no requirement to upgrade older dwellings,
  430.     though there are some exceptions (ie: smoke detectors in some
  431.     cases).  However, any new work must be done according to the
  432.     latest electrical code.  Also, if you do ``major'' work, you
  433.     may be required to upgrade certain existing portions or all
  434.     of your system.  Check with your local electrical inspector.
  435.  
  436. Subject: A word on voltages: 110/115/117/120/125/220/240
  437.  
  438.     One thing where things might get a bit confusing is the
  439.     different numbers people bandy about for the voltage of
  440.     a circuit.  One person might talk about 110V, another 117V
  441.     or another 120V.  These are all, in fact, exactly the same
  442.     thing...  In North America the utility companies are required
  443.     to supply a split-phase 240 volt (+-5%) feed to your house.
  444.     This works out as two 120V +- 5% legs.  Additionally, since there
  445.     are resistive voltage drops in the house wiring, it's not
  446.     unreasonable to find 120V has dropped to 110V or 240V has dropped
  447.     to 220V by the time the power reaches a wall outlet.  Especially
  448.     at the end of an extension cord or long circuit run.  For a number
  449.     of reasons, some historical, some simple personal orneryness,
  450.     different people choose call them by slightly different numbers.
  451.     This FAQ has chosen to be consistent with calling them "110V" and
  452.     "220V", except when actually saying what the measured voltage will
  453.     be.  Confusing?  A bit.  Just ignore it.
  454.  
  455.     One thing that might make this a little more understandable
  456.     is that the nameplates on equipment ofen show the lower (ie: 110V
  457.     instead of 120V) value.  What this implies is that the device
  458.     is designed to operate properly when the voltage drops that
  459.     low.
  460.  
  461.     208V is *not* the same as 240V.  208V is the voltage between
  462.     phases of a 3-phase "Y" circuit that is 120V from neutral to any
  463.     hot.   480V is the voltage between phases of a 3-phase "Y"
  464.     circuit that's 277V from hot to neutral.
  465.  
  466.     In keeping with 110V versus 120V strangeness, motors intended
  467.     to run on 480V three phase are often labelled as 440V...
  468.  
  469. Subject: What does an electrical service look like?
  470.  
  471.     There are logically four wires involved with supplying the
  472.     main panel with power.  Three of them will come from the utility
  473.     pole, and a fourth (bare) wire comes from elsewhere.
  474.  
  475.      The bare wire is connected to one or more long metal bars pounded
  476.      into the ground, or to a wire buried in the foundation, or sometimes
  477.      to the water supply pipe (has to be metal, continuous to where
  478.     the main water pipe entering the house.  Watch out for galvanic
  479.     action conductivity "breaks" (often between copper and iron pipe).
  480.     This is the "grounding conductor".  It is there to make sure that
  481.     the third prong on your outlets is connected to ground.  This wire
  482.     normally carries no current.
  483.  
  484.     One of the other wires will be white (or black with white or
  485.     yellow stripes, or sometimes simply black).  It is the neutral wire.
  486.     It is connected to the "centre tap" (CEC; "center tap" in the
  487.     NEC ;-) of the distribution transformer supplying the power.  It
  488.     is connected to the grounding conductor in only one place (often
  489.     inside the panel).  The neutral and ground should not be connected
  490.     anywhere else.  Otherwise, weird and/or dangerous things may happen.
  491.  
  492.     Furthermore, there should only be one grounding system in
  493.     a home.  Some codes require more than one grounding electrode.
  494.     These will be connected together, or connected to the neutral
  495.     at a common point - still one grounding system.  Adding additional
  496.     grounding electrodes connected to other portions of the house
  497.     wiring is unsafe and contrary to code.
  498.  
  499.     If you add a subpanel, the ground and neutral are usually
  500.     brought as separate conductors from the main panel, and are
  501.     not connected together in the subpanel (ie: still only one
  502.     neutral-ground connection).  However, in some situations 
  503.     (certain categories of separate buildings) you actually do
  504.     have to provide a second grounding electrode - consult your
  505.     inspector.
  506.  
  507.     The other two wires will usually be black, and are the "hot"
  508.     wires.  They are attached to the distribution transformer as
  509.     well.
  510.  
  511.     The two black wires are 180 degrees out of phase with each
  512.     other.  This means if you connect something to both hot wires,
  513.     the voltage will be 220 volts.  If you connect something to the
  514.     white and either of the two blacks you will get 110V.
  515.  
  516.     Some panels seem to only have three wires coming into them.
  517.     This is either because the neutral and ground are connected
  518.     together at a different point (eg: the meter or pole) and one
  519.     wire is doing dual-duty as both neutral and ground, or in some
  520.     rare occasions, the service has only one hot wire (110V only
  521.     service).
  522.  
  523. Subject: What is a circuit?
  524.  
  525.     Inside the panel, connections are made to the incoming wires.
  526.     These connections are then used to supply power to selected
  527.     portions of the home.  There are three different combinations:
  528.         1) one hot, one neutral, and ground: 110V circuit.
  529.         2) two hots, no neutral, and ground: 220V circuit.
  530.         3) two hots, neutral, and ground: 220V circuit + neutral,
  531.            and/or two 110V circuits with a common neutral.
  532.  
  533.     (1) is used for most circuits supplying receptacles and
  534.     lighting within your house.  (3) is usually used for supplying
  535.     power to major appliances such as stoves, and dryers - they
  536.     often have need for both 220V and 110V, or for bringing several
  537.     circuits from the panel box to a distribution point.  (2) is
  538.     usually for special 220V motor circuits, electric heaters, or
  539.     air conditioners.
  540.  
  541.     [Note: In the US, the NEC frequently permits a circuit similar
  542.     to (2) be used for stoves and dryers - namely, that there
  543.     are two hot wires, and a wire that does dual duty as neutral
  544.     and ground, and is connected to the frame as well as providing
  545.     the neutral for 110V purposes - three prong plugs instead
  546.     of four (*only* for stoves/dryers connected to the main panel.
  547.     When connected to most sub-panels, 4 prong plugs and receptacles
  548.     are required).  In our not-so-humble opinion this is crazy, but
  549.     the NFPA claims that this practice was re-evaluated for the 1992 NEC,
  550.     and found to be safe.  Check your local codes, or inquire as to
  551.     local practice -- there are restrictions on when this is
  552.     permissible.]
  553.  
  554.     (1) is usually wired with three conductor wire: black for hot,
  555.     white for neutral, and bare for grounding.
  556.  
  557.     (2) and (3) have one hot wire coloured red, the other black, a
  558.     bare wire for grounding, and in (3) a white wire for neutral.
  559.  
  560.     You will sometimes see (2) wired with just a black, white and ground
  561.     wire.  Since the white is "hot" in this case, both the NEC and CEC
  562.     requires that the white wire be "permanently marked" at the ends
  563.     to indicate that it is a live wire.  Usually done with paint, nail
  564.     polish or sometimes electrical tape.
  565.  
  566.     Each circuit is attached to the main wires coming into the
  567.     panel through a circuit breaker or fuse.
  568.  
  569.     There are, in a few locales, circuits that look like (1), (2)
  570.     or (3) except that they have two bare ground wires.  Some places
  571.     require this for hot tubs and the like (one ground is "frame ground",
  572.     the other attaches to the motor).  This may or may not be an
  573.     alternative to GFCI protection.
  574.  
  575. Subject: "grounding" versus "grounded" versus "neutral".
  576.  
  577.     According to the terminology in the CEC and NEC, the
  578.     "grounding" conductor is for the safety ground, i.e., the green
  579.     or bare or green with a yellow stripe wire.  The word "neutral"
  580.     is reserved for the white when you have a circuit with more than 
  581.     one "hot" wire.  Since the white wire is connected to neutral and
  582.     the grounding conductor inside the panel, the proper term is
  583.     "grounded conductor".  However, the potential confusion between
  584.     "grounded conductor" and "grounding conductor" can lead to
  585.     potentially lethal mistakes - you should never use the bare wire
  586.     as a "grounded conductor" or white wire as the "grounding conductor",
  587.     even though they are connected together in the panel.
  588.  
  589.     [But not in subpanels - subpanels are fed neutral and ground
  590.     separately from the main panel.  Usually.]
  591.  
  592.     Note: do not tape, colour or substitute other colour wires for the
  593.     safety grounding conductor.
  594.  
  595.     In the trade, and in common usage, the word "neutral" is used
  596.     for "grounded conductor".  This FAQ uses "neutral" simply to
  597.     avoid potential confusion.  We recommend that you use "neutral"
  598.     too.  Thus the white wire is always (except in some light
  599.     switch applications) neutral.  Not ground.
  600.  
  601. Subject: What does a fuse or breaker do?  What are the differences?
  602.  
  603.     Fuses and circuit breakers are designed to interrupt the power
  604.     to a circuit when the current flow exceeds safe levels.  For
  605.     example, if your toaster shorts out, a fuse or breaker should
  606.     "trip", protecting the wiring in the walls from melting.  As
  607.     such, fuses and breakers are primarily intended to protect the
  608.     wiring -- UL or CSA approval supposedly indicates that the
  609.     equipment itself won't cause a fire.
  610.  
  611.     Fuses contain a narrow strip of metal which is designed to melt
  612.     (safely) when the current exceeds the rated value, thereby
  613.     interrupting the power to the circuit.  Fuses trip relatively
  614.     fast.  Which can sometimes be a problem with motors which have
  615.     large startup current surges.  For motor circuits, you can use
  616.     a "time-delay" fuse (one brand is "fusetron") which will avoid
  617.     tripping on momentary overloads.  A fusetron looks like a
  618.     spring-loaded fuse.  A fuse can only trip once, then it must be
  619.     replaced.
  620.  
  621.     Breakers are fairly complicated mechanical devices.  They
  622.     usually consist of one spring loaded contact which is latched
  623.     into position against another contact.  When the current flow
  624.     through the device exceeds the rated value, a bimetallic strip
  625.     heats up and bends.  By bending it "trips" the latch, and the
  626.     spring pulls the contacts apart.  Circuit breakers behave
  627.     similarly to fusetrons - that is, they tend to take longer to
  628.     trip at moderate overloads than ordinary fuses.  With high
  629.     overloads, they trip quickly.  Breakers can be reset a finite
  630.     number of times - each time they trip, or are thrown
  631.     when the circuit is in use, some arcing takes place, which
  632.     damages the contacts.  Thus, breakers should not be used in
  633.     place of switches unless they are specially listed for the
  634.     purpose.
  635.  
  636.     Neither fuses nor breakers "limit" the current per se.  A dead
  637.     short on a circuit can cause hundreds or sometimes even
  638.     thousands of amperes to flow for a short period of time, which
  639.     can often cause severe damage.
  640.  
  641. Subject: Breakers?  Can't I use fuses?
  642.  
  643.     Statistics show that fuse panels have a significantly higher
  644.     risk of causing a fire than breaker panels.  This is usually
  645.     due to the fuse being loosely screwed in, or the contacts
  646.     corroding and heating up over time, or the wrong size fuse
  647.     being installed, or the proverbial "replace the fuse with a
  648.     penny" trick.
  649.  
  650.     Since breakers are more permanently installed, and have better
  651.     connection mechanisms, the risk of fire is considerably less.
  652.  
  653.     Fuses are prone to explode under extremely high overload.  When
  654.     a fuse explodes, the metallic vapor cloud becomes a conducting
  655.     path.  Result?  From complete meltdown of the electrical panel,
  656.     melted service wiring, through fires in the electrical
  657.     distribution transformer and having your house burn down.
  658.     [This author has seen it happen.]  Breakers won't do this.
  659.  
  660.     Many jurisdictions, particularly in Canada, no longer permit
  661.     fuse panels in new installations.  The NEC does permit new
  662.     fuse panels in some rare circumstances (requiring the special
  663.     inserts to "key" the fuseholder to specific size fuses)
  664.  
  665.     Some devices, notably certain large air conditioners, require fuse
  666.     protection in addition to the breaker at the panel.  The fuse
  667.     is there to protect the motor windings from overload.  Check the
  668.     labeling on the unit.  This is usually only on large permanently
  669.     installed motors.  The installation instructions will tell you
  670.     if you need one.
  671.  
  672. Subject: What size wire should I use?
  673.  
  674.     For a 20 amp circuit, use 12 gauge wire.  For a 15 amp circuit,
  675.     you can use 14 gauge wire (in most locales).  For a long run,
  676.     though, you should use the next larger size wire, to avoid
  677.     voltage drops.  12 gauge is only slightly more expensive than
  678.     14 gauge, though it's stiffer and harder to work with.
  679.  
  680.     Here's a quick table for normal situations.  Go up a size for
  681.     more than 100 foot runs, when the cable is in conduit, or
  682.     ganged with other wires in a place where they can't dissipate
  683.     heat easily:
  684.  
  685.         Gauge        Amps
  686.         14        15
  687.         12        20
  688.         10        30
  689.         8        40
  690.         6        65
  691.     
  692.     We don't list bigger sizes because it starts getting very dependent
  693.     on the application and precise wire type.
  694.  
  695. Subject: Where do these numbers come from?
  696.  
  697.     There are two considerations, voltage drop and heat buildup.
  698.     The smaller the wire is, the higher the resistance is.  When
  699.     the resistance is higher, the wire heats up more, and there is
  700.     more voltage drop in the wiring.  The former is why you need
  701.     higher-temperature insulation and/or bigger wires for use in
  702.     conduit; the latter is why you should use larger wire for long
  703.     runs.
  704.  
  705.     Neither effect is very significant over very short distances.
  706.     There are some very specific exceptions, where use of smaller
  707.     wire is allowed.  The obvious one is the line cord on most
  708.     lamps.  Don't try this unless you're certain that your use fits
  709.     one of those exceptions; you can never go wrong by using larger
  710.     wire.
  711.  
  712. Subject: What does "14-2" mean?
  713.  
  714.     This is used to describe the size and quantity of conductors
  715.     in a cable.  The first number specifies the gauge.  The second
  716.     the number of current carrying conductors in the wire - but
  717.     remember there's usually an extra ground wire.  "14-2" means
  718.     14 gauge, two insulated current carrying wires, plus bare ground.
  719.  
  720.     -2 wire usually has a black, white and bare ground wire.  Sometimes
  721.     the white is red instead for 220V circuits without neutral.  In
  722.     the latter case, the sheath is usually red too.
  723.  
  724.     -3 wire usually has a black, red, white and bare ground wire.
  725.     Usually carrying 220V with neutral.
  726.  
  727. Subject: What is a "wirenut"/"marrette"/"marr connector"?  How are they
  728.     used?
  729.  
  730.     A wire nut is a cone shaped threaded plastic thingummy that's used
  731.     to connect wires together.  "Marrette" or "Marr connector"
  732.     are trade names.  You'll usually use a lot of them in DIY wiring.
  733.  
  734.     In essence, you strip the end of the wires about an inch, twist them
  735.     together, then twist the wirenut on.
  736.  
  737.     Though some wirenuts advertise that you don't need to twist the
  738.     wire, do it anyways - it's more mechanically and electrically
  739.     secure.
  740.  
  741.     There are many different sizes of wire nut.  You should check
  742.     that the wire nut you're using is the correct size for the
  743.     quantity and sizes of wire you're connecting together.
  744.  
  745.     Don't just gimble the wires together with a pair of pliers or
  746.     your fingers.  Use a pair of blunt nose ("linesman") pliers,
  747.     and carefully twist the wires tightly and neatly.  Sometimes
  748.     it's a good idea to trim the resulting end to make sure it
  749.     goes in the wirenut properly.
  750.  
  751.     Some people wrap the "open" end of the wirenut with electrical
  752.     tape.  This is probably not a good idea - the inspector may
  753.     tear it off during an inspection.  It's usually done because
  754.     a bit of bare wire is exposed outside the wire nut - instead
  755.     of taping it, the connection should be redone.
  756.  
  757. Subject: What is a GFI/GFCI?
  758.  
  759.     A GFCI is a ``ground-fault circuit interrupter''.  It measures
  760.     the current current flowing through the hot wire and the
  761.     neutral wire.  If they differ by more than a few milliamps, the
  762.     presumption is that current is leaking to ground via some other
  763.     path.  This may be because of a short circuit to the chassis of
  764.     an appliance, or to the ground lead, or through a person.  Any
  765.     of these situations is hazardous, so the GFCI trips, breaking
  766.     the circuit.
  767.  
  768.     GFCIs do not protect against all kinds of electric shocks.  If,
  769.     for example, you simultaneously touched the hot and neutral
  770.     leads of a circuit, and no part of you was grounded, a GFCI
  771.     wouldn't help.  All of the current that passed from the hot
  772.     lead into you would return via the neutral lead, keeping the
  773.     GFCI happy.
  774.  
  775.     The two pairs of connections on a GFCI outlet are not symmetric.
  776.     One is labeled LOAD; the other, LINE.  The incoming power feed
  777.     *must* be connected to the LINE side, or the outlet will not be
  778.     protected.  The LOAD side can be used to protect all devices
  779.     downstream from it.  Thus, a whole string of outlets can be
  780.     covered by a single GFCI outlet.
  781.  
  782. Subject: Where should GFCIs be used?
  783.  
  784.     The NEC mandates GFCIs for 110V, 15A or 20A single phase
  785.     outlets, in bathrooms, kitchens within 6' of the sink, wet-bar
  786.     sinks, roof outlets, garages, unfinished basements or crawl spaces,
  787.     outdoors, near a pool, or just about anywhere else where you're likely
  788.     to encounter water or dampness.  There are exceptions for inaccessible
  789.     outlets, those dedicated to appliances ``occupying fixed space'',
  790.     typically refrigerators and freezers, and for sump pumps and
  791.     laundry appliances.
  792.  
  793.     The NEC now requires that if your replace an outlet in a
  794.     location now requiring GFCI, you must install GFCI protection.
  795.     Note in particular - kitchen and bathroom outlets.
  796.  
  797.     When using the "fixed appliance" rule for avoiding GFCI outlets,
  798.     single outlet receptacles must be used for single appliances,
  799.     duplex receptacles may be used for two appliances.
  800.  
  801.     The CEC does not mandate as many GFCIs.  In particular, there
  802.     is no requirement to protect kitchen outlets, or most garage or
  803.     basement outlets.  Basement outlets must be protected if you
  804.     have a dirt floor, garage outlets if they're near the door to
  805.     outside.  Bathrooms and most exterior outlets must have GFCIs,
  806.     as do pools systems and jacuzzi or whirlpool pumps.
  807.  
  808.     There are many rules about GFCIs with pools and so on.  This
  809.     is outside of our expertise, so we're not covering it in
  810.     detail.  See your inspector.
  811.  
  812.     When replacing an outlet, it must now be GFCI-protected if
  813.     such would now be required for a new installation.  That is,
  814.     a kitchen outlet installed per the 1984 code need not have
  815.     been protected, but if that outlet is ever replaced, GFCI
  816.     protection must now be added (under NEC).  This is explicit
  817.     in the 1993 NEC, and inspector-imposed in Canada.
  818.  
  819.     Even if you are not required to have GFCI protection, you may
  820.     want to consider installing it anyway.  Unless you need a GFCI
  821.     breaker (see below), the cost is low.  In the U.S., GFCI
  822.     outlets can cost as little as US$8.  (Costs are a bit higher in
  823.     Canada:  C$12.)  Evaluate your own risk factors.  Does your
  824.     finished basement ever get wet?  Do you have small children?
  825.     Do you use your garage outlets to power outdoor tools?  Does
  826.     water or melted snow ever puddle inside your garage?
  827.  
  828. Subject: Where shouldn't I use a GFCI?
  829.  
  830.     GFCIs are generally not used on circuits that (a) don't pose a
  831.     safety risk, and (b) are used to power equipment that must run
  832.     unattended for long periods of time.  Refrigerators, freezers,
  833.     and sump pumps are good examples.  The rationale is that GFCIs
  834.     are sometimes prone to nuisance trips.  Some people claim that
  835.     the inductive delay in motor windings can cause a momentary
  836.     current imbalance, tripping the GFCI.  Note, though, that most
  837.     GFCI trips are real; if you're getting a lot of trips for no
  838.     apparent reason, you'd be well-advised to check your wiring
  839.     before deciding that the GFCI is broken or useless.
  840.  
  841. Subject: What is the difference between a GFCI outlet and a GFCI breaker?
  842.  
  843.     For most situations, you can use either a GFCI outlet as the
  844.     first device on the circuit, or you can install a breaker with
  845.     a built-in GFCI.  The former is generally preferred, since GFCI
  846.     breakers are quite expensive.  For example, an ordinary GE
  847.     breaker costs ~US$5; the GFCI model costs ~US$35.  There is one
  848.     major exception:  if you need to protect a ``multi-wire branch
  849.     circuit'' (two or more circuits sharing a common neutral wire),
  850.     such as a Canadian-style kitchen circuit, you'll need a
  851.     multi-pole GFCI breaker.  Unfortunately, these are expensive;
  852.     the cost can range into the hundreds of dollars, depending on
  853.     what brand of panel box you have.  But if you must protect such
  854.     a circuit (say, for a pool heater), you have no choice.
  855.  
  856.     One more caveat -- GFCI outlets are bulky.  You may want to use
  857.     an oversize box when installing them.  On second thought, use
  858.     large (actually deep) boxes everywhere.  You'll thank yourself
  859.     for it.
  860.  
  861.     Incidentally, if you're installing a GFCI to ensure that one
  862.     specific outlet is protected (such as a bathroom), you don't
  863.     really have to go to all of the trouble to find the first
  864.     outlet in the circuit, you could simply find the first outlet
  865.     in the bathroom, and not GFCI anything upstream of it.  But
  866.     protecting the whole circuit is preferred.
  867.  
  868.     When you install a GFCI, it's a good idea to use the little
  869.     "ground fault protected" stickers that come with it and mark
  870.     the outlets downstream of the GFCI.  You can figure out which
  871.     outlets are "downstream", simply by tripping the GFCI with the
  872.     test button and see which outlets are dead.
  873.  
  874.     Note that the labels are mandatory for GFCI-protected-but-ungrounded
  875.     three prong outlets according to the NEC.
  876.  
  877. Subject: What's the purpose of the ground prong on an outlet, then?
  878.  
  879.     Apart from their use in electronics, which we won't comment on,
  880.     and for certain fluorescent lights (they won't turn on without
  881.     a good ground connection), they're intended to guard against
  882.     insulation failures within the device.  Generally, the case of
  883.     the appliance is connected to the ground lead.  If there's an
  884.     insulation failure that shorts the hot lead to the case, the
  885.     ground lead conducts the electricity away safely (and possibly
  886.     trips the circuit breaker in the process).  If the case is not
  887.     grounded and such a short occurs, the case is live -- and if
  888.     you touch it while you're grounded, you'll get zapped.  Of
  889.     course, if the circuit is GFCI-protected, it will be a very
  890.     tiny zap -- which is why you can use GFCIs to replace
  891.     ungrounded outlets (both NEC and CEC).
  892.  
  893.     There are some appliances that should *never* be grounded.  In
  894.     particular, that applies to toasters and anything else with
  895.     exposed conductors.  Consider:  if you touch the heating
  896.     electrode in a toaster, and you're not grounded, nothing will
  897.     happen.  If you're slightly grounded, you'll get a small shock;
  898.     the resistance will be too high.  But if the case were
  899.     grounded, and you were holding it, you'd be the perfect path to
  900.     ground...
  901.  
  902. Subject: Why is one prong wider than the other?  Polarization
  903.  
  904.     Nowadays, many two-prong devices have one prong wider than the
  905.     other.  This is so that the device could rely (not guaranteed!)
  906.     on one specific wire being neutral, and the other hot.
  907.     This is particularly advantageous in light fixtures, where the
  908.     the shell should neutral (safety), or other devices which want to
  909.     have an approximate ground reference (ie: some radios).
  910.  
  911.     Most 2-prong extension cords have wide prongs too.
  912.  
  913.     This requires that you wire your outlets and plugs the right
  914.     way around.  You want the wide prong to be neutral, and the
  915.     narrow one hot.  Most outlets have a darker metal for the
  916.     hot screw, and lighter coloured screw for the neutral.
  917.     If not, you can usually figure out which is which by which
  918.     prong the terminating screw connects to.
  919.  
  920. Subject: How do I convert two prong receptacles to three prong?
  921.  
  922.     Older homes frequently have two-prong receptacles instead
  923.     of the more modern three.  These receptacles have no safety
  924.     ground, and the cabling usually has no ground wire.  Neither
  925.     the NEC or CEC permits installing new 2 prong receptacles anymore.
  926.  
  927.     There are several different approaches to solving this:
  928.         1) If the wiring is done through conduit or BX, and the
  929.            conduit is continuous back to the panel, you can connect
  930.            the third prong of a new receptacle to the receptacle
  931.            box.  NEC mainly - CEC frowns on this practice.
  932.         2) If there is a copper cold water pipe going nearby, and
  933.            it's continuous to the main house ground point, you can
  934.            run a conductor to it from the third prong.
  935.            NEC: this can only be done if the point of attachment
  936.            is within 5 feet of where the pipe enters the ground.
  937.         3) Run a ground conductor back to the main panel.
  938.         4) Easiest: install a GFCI receptacle.  The ground lug
  939.            should not be connected to anything, but the GFCI
  940.            protection itself will serve instead.  The GFCI
  941.            will also protect downstream (possibly also two prong
  942.            outlets).  If you do this to protect downstream outlets,
  943.            the grounds must not be connected together.  Since it
  944.            wouldn't be connected to a real ground, a wiring fault
  945.            could energize the cases of 3 prong devices connected
  946.            to other outlets.  Be sure, though, that there aren't
  947.            indirect ground plug connections, such as via the sheath
  948.            on BX cable.
  949.  
  950.     The CEC permits you to replace a two prong receptacle with a three
  951.     prong if you fill the U ground with a non-conducting goop.
  952.     Like caulking compound.  This is not permitted in the NEC.
  953.  
  954.     The NEC requires that three prong receptacles without ground
  955.     that are protected by GFCI must be labelled as such.
  956.  
  957.     See the next section about computers on GFCI-protected groundless
  958.     outlets.
  959.  
  960. Subject: Surges, spikes, zaps, grounding and your electronics (NEW)
  961.  
  962.     Theoretically, the power coming into your house is a perfect
  963.     AC sine wave.  It is usually quite close.  But occasionally,
  964.     it won't be.  Lightning strikes and other events will affect
  965.     the power.  These usually fall into two general categories: very
  966.     high voltage spikes (often into 1000s of volts, but usually
  967.     only a few microseconds in length) or surges (longer duration,
  968.     but usually much lower voltage).
  969.  
  970.     Most of your electrical equipment, motors, transformer-operated
  971.     electronics, lights, etc., won't even notice these one-shot events.
  972.     However, certain types of solid-state electronics, particularly
  973.     computers with switching power supplies and MOS semiconductors,
  974.     can be damaged by these occurances.  For example, a spike can
  975.     "punch a hole" through an insulating layer in a MOS device (such
  976.     as that several hundred dollar 386 CPU), thereby destroying it.
  977.  
  978.     The traditional approach to protecting your electronics is to use
  979.     "surge suppressors" or "line filters".  These are usually devices
  980.     that you plug in between the outlet and your electronics.
  981.  
  982.     Roughly speaking, surge suppressors work by detecting overvoltages,
  983.     and shorting them out.  Think of them as voltage limiters.  Line
  984.     filters usually use frequency-dependent circuits (inductors, capacitors
  985.     etc.) to "tune out" undesirable spikes - preventing them from reaching
  986.     your electronics.
  987.  
  988.     So, you should consider using suppressors or filters on your sensitive
  989.     equipment.
  990.  
  991.     These devices come in a very wide price range.  From a couple
  992.     of dollars to several hundred.  We believe that you can protect
  993.     your equipment from the vast majority of power problems by selecting
  994.     devices in the $20-50 range.
  995.  
  996.     A word about grounding: most suppressors and EFI filters require real
  997.     grounds.  Any that don't are next to useless.
  998.  
  999.     For example, most surge suppressors use MOVs (metal oxide varistors)
  1000.     to "clamp" overvoltages.  Yes, you can have a suppressor that only
  1001.     has a MOV between neutral and hot to combat differential-mode voltage
  1002.     excursions, but that isn't enough.  You need common-mode protection
  1003.     too.  Good suppressors should have 3 MOVs, one between each pair of wires.
  1004.     Which means you should have a good solid ground.  Eg: a solidly connected
  1005.     14ga wire back to the panel.  Not rusty BX armour or galvanized pipe
  1006.     with condensation turning the copper connection green.
  1007.  
  1008.     Without a ground, a surge or spike is free to "lift" your entire electronics
  1009.     system well away from ground.  Which is ideal for blowing out interface
  1010.     electronics for printer ports etc.
  1011.  
  1012.     Secondly, static electricity is one of the major enemies of electronics.
  1013.     Having good frame grounds is one way of protecting against static zaps.
  1014.  
  1015.     If you're in the situation of wanting to install computer equipment
  1016.     on two wire groundless circuits take note:
  1017.     
  1018.     Adding a GFCI outlet to the circuit makes the circuit safe for you.
  1019.     But it doesn't make it safe for your equipment - you need a ground to
  1020.     make surge suppressors or line filters effective.
  1021.  
  1022. Subject: Are you sure about GFCIs and ungrounded outlets?
  1023.     Should the test button work?
  1024.  
  1025.     The NEC, section 210-7(d), and CEC, section 26-700(9), are quite
  1026.     explicit that GFCIs are a legal substitute for a grounded outlet
  1027.     in an existing installation where there is no ground available in
  1028.     the outlet box.
  1029.  
  1030.     But your local codes may vary.  As for the TEST button -- there's
  1031.     a resistor connecting the LOAD side of the hot wire to the LINE
  1032.     side of the neutral wire when you press the TEST button.  Current
  1033.     through this resistor shows up as an imbalance, and trips the GFCI.
  1034.     This is a simple, passive, and reliable test, and doesn't require
  1035.     a real ground to work.  If your GFCI does not trip when you press
  1036.     the TEST button, it is very probably defective or miswired.  Again:
  1037.     if the test button doesn't work, something's broken, and potentially
  1038.     dangerous.  The problem should be corrected immediately.
  1039.  
  1040.     The instructions that come with some GFCIs specify that the ground
  1041.     wire must be connected.  We do not know why they say this.  The
  1042.     causes may be as mundane as an old instruction sheet, or with the
  1043.     formalities of UL or CSA listing -- perhaps the device was never
  1044.     tested without the ground wire being connected.  On the other hand,
  1045.     UL or CSA approval should only have been granted if the device
  1046.     behaves properly in *all* listed applications, including ungrounded
  1047.     outlet replacement.  (One of us called Leviton; their GFCIs are
  1048.     labeled for installation on grounded circuits only.  The technician
  1049.     was surprised to see that; he agreed that the NEC does not require
  1050.     it, and promised to investigate.)
  1051.  
  1052. -- 
  1053. Look on the bright side - at least the PC's reached gender parity!
  1054. Chris Lewis; clewis@ferret.ocunix.on.ca; Phone: Canada 613 832-0541
  1055. Ferret list: ferret-request@ferret.ocunix.on.ca
  1056. Latest psroff: FTP://ftp.uunet.ca/distrib/chris_lewis/psroff3.0pl17/*
  1057.  
  1058.